Two methods of centralized management of UPS power system

2020-06-29  views:2345

Huabao Golden Samurai UPS Power 2020.6.29


UPS power supplies are not only used in large data centers, but are also slowly becoming popular in many small and medium-sized enterprises. Therefore, the management of UPS power system is becoming more and more important. Correspondingly, the development of enterprise internal network provides a new idea for UPS power management-centralized network management. Some companies are already using this method to "tame" the UPS power system, so what are the advantages of the specific operation methods and solutions?


If all information can be collected through a program and displayed with a simple graphical interface, plus a warning function, then the administrator can easily manage hundreds or even thousands of network UPS power supplies through this centralized management program. Compared with the previous one to check the power status of the UPS, the efficiency of centralized management has been greatly improved.

UPS power centralized management online management through 3 ways: UPS and computer in series


You can install a multi-port card on the computer to expand the RS232 interface, or connect multiple UPS power supplies to RS485 and then connect to the computer's RS232 interface. RS485 is suitable for connecting remote UPS power supplies, but as the number of UPS power supplies connected in series increases, the time efficiency of the system to monitor UPS power will change. The more UPS power supplies are connected, the time required for the system to monitor UPS power will change. Longer.


Collect UPS information through the network


We can insert SNMP card or install UPS power supply software to collect UPS power supply information through the network, so the centralized management software must have both monitoring software and SNMP card online capabilities. Once more and more points are monitored, network traffic becomes a big problem in the management system. In order to avoid network traffic congestion, the management software should be able to adjust the monitoring time and reduce the transmission of network packets at any time. After all, smoothing the internal operations of the enterprise is the number one priority.


Improve efficiency through UPS management software


Administrators can plan protection actions when power problems occur through centralized UPS power management. After the power problem is over, the management can track and find the problematic UPS power source step by step, and analyze the cause of the power event. Under the protection of UPS power supply, the manager will be notified of every power event that occurs at the first time and provide sufficient information to let him know how to handle the equipment.


For enterprise managers, the management of UPS power system can be remotely operated through the network. Of course, enterprises with conditions can also purchase a more intelligent UPS power system for semi-automatic management, which can save a lot of money Labor costs. However, due to security and reliability considerations, enterprises will not consider fully intelligent automatic management methods for the time being.